CodeNameDescriptionCapabilityInstruments
AC-1AC-1: AC Impedence Spectrometer, 10kohm -100MohmImpedence: 10kohm -100MohmPLATYPUS, SPATZ
AVM-1AVM-1: 12T asym, vertical field magnet, 1.5K – 300K; B<12T12 Tesla vertical field recondensing magnet: 0.5T/min; it can accommodate Dilution Insert DL-1Temp Range: 1.5K - 300KECHIDNA, SIKA, TAIPAN, WOMBAT
AVM-2AVM-2: 7T vertical magnetCommissioned for Pelican and Quokka. The magnet is currently under commissioning. Please discuss bookings with SE team prior to scheduling. PELICAN, QUOKKA
BT-1Cadex C8000 battery testingDINGO, ECHIDNA, KOWARI, QUOKKA, SIKA, TAIPAN, WOMBAT
Be-FilterBeryllium Filter SpectrometerBeryllium Filter Spectrometer option for TAIPANEnergy Range: 5.0 - 70 meVTAIPAN
CF-1CF-1: Cryofurnace, bottom loader, 5K - 300K or 20K - 750KStandard bottom loader for TAIPAN and SIKA; Can be used with EF-1.Temp Range: 5K - 300K
Temp Range: 20K - 750K
EMU, KOOKABURRA, SIKA, TAIPAN
CF-10CF-10: Cryocooler, top loading, 1.5K - 300KTop Loading cryostat, it can be used with Dilution Insert DL-1 and polarization coilsTemp Range: 1.5K - 300KECHIDNA, EMU, PELICAN, SIKA, TAIPAN, WOMBAT
CF-11CF-11: Cryofurnace, top loader, 1.5K - 800KCF-11: Cryofurnace, top loader, 1.5K - 800K. Preferred use is for Pelican but is also available for Taipan, Sika, Wombat, Echidna and Emu.Temp range: 1.5K - 800KPELICAN, SIKA
CF-12CF-12: Cryofurnace, top loader, 1.5K - 800KCF-12: Cryofurnace, top loader, 1.5K - 800K. Preferred use is for Emu, but can also go on Sika, Taipan, Echidna, Wombat, and Pelican.Temp range: 1.5K - 800KECHIDNA, EMU, SIKA, TAIPAN, WOMBAT
CF-13CF-13: Cryofurnace 1.5K to 800K Under commissioningECHIDNA, SIKA
CF-2CF-2: Cryofurnace, bottom loader, 5K - 300K or 20K - 750KStandard bottom loader for KoalaTemp Range: 5K - 300K
Temp Range: 20K - 750K
KOALA
CF-3CF-3: Cryofurnace, bottom loader, 5K - 300K or 20K - 750KPooled bottom loader for general use, but currently modified for preferential use on Pelican Temp Range: 5K - 300K
Temp Range: 20K - 750K
EMU, PELICAN, SIKA
CF-5CF-5: Cryocooler for eulerian cradle, 8K - 300KBottom loader to be used with the eulerian cradlesTemp Range: 8K - 300KDINGO, ECHIDNA, KOWARI, SIKA, TAIPAN, WOMBAT
CF-6CF-6: Cryocooler for Reflectometry/SANS, 5K - 300KBottom loader designed to fit into the electromagnet HM-3, can be used with EF-1; it has a manual sample rotation stageTemp Range: 5K - 300KBILBY, PLATYPUS, QUOKKA
CF-7CF-7: Cryofurnace, top loading, 4K - 450KTop Loading AS Scientific Cryofurnace - preferred for Echidna, it can reach 750K with TL-1 sample stickTemp Range: 4K to 450KECHIDNA, SIKA, TAIPAN
CF-8CF-8: Cryofurnace, top loading, 4K - 450KTop Loading Cryofurnace - preferred for Wombat, it can reach 750K with TL-1Temp Range: 4K - 450KSIKA, TAIPAN, WOMBAT
CobraCobra: Cobra, N2 gas flow, 80K - 400 KOxford Cryosystems Cobra Plus, nitrogen gas flow Temp Range: 80K - 400KKOALA
DC-1DC-1: Triton dilution cryostat (~20mK to 30K)Dilution cryostat with top-loading sample change capability. 1 day install and ~26hrs for initial cooldown to dilution temperatures. ~12hrs for sample change and cooldown back to dilution temperatures.ECHIDNA, PELICAN, WOMBAT
DL-1DL-1: He-3/He-4 Dilution Insert, 50mK - 1KDilution Insert - only to be booked in conjunction with Cryocooler CF-10, CF-11, CF-12 or 12T Vertical magnet AVM-1. Please discuss with SE before booking. Remote temperature control out of service 10/9/2020. Servicing of this unit booked from 16/10/2020, please consult SE before scheduling from this date. Temp Range: 50mK - 1KECHIDNA, EMU, PELICAN, SIKA, TAIPAN, WOMBAT
DSC-1DSC-1: Differential Scanning Calorimeter, -50°C - +350°CDSC for in-situ SANS experimentsTemp Range: -50C - +350CQUOKKA
EC-1EC-1: C shaped Eulerian CradleC shaped eulerian cradle; can accommodate CF-5ECHIDNA, KOWARI, QUOKKA, SIKA, TAIPAN, WOMBAT
EC-3EC-3: Small Eulerian CradleSmall full circle eulerian cradle - usually only used on KowariKOWARI
EF-1EF-1: Electric Field, 10 kV10kV DC variable power supply system Voltage: up to 10kVBILBY, ECHIDNA, KOWARI, QUOKKA, TAIPAN, WOMBAT
F-1F-1: Vacuum Furnace F-1 , RT - 1600°CILL type, niobium shielded vacuum furnace, can reach 1800°C for short periods only (t < 30 minutes) ECHIDNA, PELICAN, SIKA, TAIPAN, WOMBAT
F-4F-4: Halogen lamp furnace for horizontal load frame, RT - 1000°CHalogen lamp furnace to be used with Kowari load frame (P-2)KOWARI
F-5F-5: Low Temperature Vacuum Furnace, RT – 500°CCovers the low T range, which is difficult to regulated with the ILL type vacuum furnace, it has gas loading capabilityWOMBAT
F-6F-6: Environmental Chamber, RT – 100°CIn house designed environmental chamber, can used for bulky samples, can be used on Load Frame P-2, (Please discuss with Sample Envirionment group before booking)ECHIDNA, KOWARI, TAIPAN, WOMBAT
GD-1GD-1: Gas Delivery and Sorption/Desorption System, max. pressure 200 barHiden Isochema IMI-HTP volumetric/manometric system for in-situ sorption/desorption measurements Pressure: max 200 barBILBY, ECHIDNA, PELICAN, PLATYPUS, QUOKKA, SIKA, SPATZ, TAIPAN, WOMBAT
GS-1GS-1: Dynamic Sampling Gas Spectrometer, 1-200 AMUHiden Gas Spectrometer HPR-20 100 mbar - 2 barPressure Range: 100 mbar - 2 barBILBY, ECHIDNA, PLATYPUS, QUOKKA, SIKA, SPATZ, TAIPAN, WOMBAT
HM-1HM-1: 5T horizontal field cryomagnet (dry), B < 5T5 Tesla, 80 mm warm bore, can be used with CF-1/CF-3 cryofurnaceBILBY, KOOKABURRA, QUOKKA
HM-2HM-2: 10T horizontal field magnet (wet), 1.5K – 300K; B <10T10 Tesla horizontal field magnet, can reach 11 T with lambda plate, can use 3he one-shot for 500mK - 80K temps.BILBY, QUOKKA
HM-3HM-3: 1T Electromagnet, B < 1T1 Tesla Bruker Electromagnet, can be used with cryocooler CF-6. Predominantly used on Platypus as a horizontal magnet. Can be used on Quokka, Bilby and Wombat (for polarisation experiments) as a vertical magnet.BILBY, PLATYPUS, QUOKKA, WOMBAT
IR-1IR-1 Infra-red SpectrometerSPATZ
LF-1LF-1: Langmuir Film BalanceNIMA Type 601PLATYPUS
LF-2LF-2: Small Langmuir Film BalanceNIMA Model 301MPLATYPUS
OC-1OC-1: Orange Cryostat, 1.5K - 300KLiquid Helium cryostat, can also take 3He one-shot for 500mK temps.T range: 1.5K - 300KECHIDNA, SIKA, TAIPAN, WOMBAT
OS-1OS-1: 3He one-shot fridge, 0.5K - 80KHelium 3 one-shot fridge (0.5 K for 8 hours) to be used with the Orange Cryostat OC-1 or 10T Horizontal Magnet HM-2 (Quokka)Temp Range: 0.5K - 80KECHIDNA, QUOKKA, SIKA, TAIPAN, WOMBAT
P-2P-2: Kowari 100kN Load Frame, RT - 1000ºC100kN load frame for tension, compression and fatigue tests at room temperature to high temperatureKOWARI
P-3P-3: Paris-Edinburgh High Pressure Cell, 10GPa (130 Tonne)Manually operated PE cell (VX-5); room temperature only. Can be used on Wombat, Echidna, Taipan and Sika.Pressue: 10 GPaSIKA, TAIPAN, WOMBAT
P-4P-4: 3/8" Vanadium can, 15 barSealable 3/8" Vanadium sample can with a volume of 4 mLPressure: 15 barECHIDNA, PELICAN, SIKA, TAIPAN, WOMBAT
P-5P-5: 1/4" Vanadium can, 30 barSealable Vanadium sample can with a volume of 1.5 mLPressure: 30 barECHIDNA, PELICAN, SIKA, TAIPAN, WOMBAT
RH-1RH-1: Shear cell / rheometer, -40°C - +80°CRheometer for SANS experiments based on Anton_Paar MCR 500 modelTemp Range: -40C - +80CBILBY, KOOKABURRA, QUOKKA, WOMBAT
RQ-1RQ-1: Rapid Heat and Quench Cell, 150K - 700KRapid thermal system for SANS, it allows rapid quenching/heating of samplesTemp Range: 150K - 700KQUOKKA
RQ-2RQ-2: Rapid quencher, RT - 500°CThis furnace allows the rapid quenching of samples through a LN2 regulated flow (OUT OF SERVICE - discuss with Sample Environment group before booking)DINGO, KOWARI
RV-1RV-1: Rapid Viscosity AnalyserRapid Viscosity AnalyserQUOKKA
SC-1SC-1: 10 position SANS sample changer, RT - 450°CThermally controlled sample changer for 10 samplesTemp Range: RT - 450CBILBY
SC-10SC-10: RALF 6-axis robot armECHIDNA
SC-2SC-2: 20 position SANS sample changer , -40°C - +120°CThermally controlled sample changer for 20 samplesTemp Range: -10C - +80CQUOKKA
SC-3SC-3: Sealed Multiple Troughs, RT5 position liquid-air troughPLATYPUS
SC-4SC-4: Robot Sample Changer (Robbie), RT4 axis robot (Robbie), 2x50 standard Vanadium can sample trays, preferred on EchidnaECHIDNA
Previous functionality disabledPreviousNext 41Select to view next set