Sample Environment: QUOKKA

Small-angle neutron-scattering instrument
CodeNameDescriptionCapability
AVM-2AVM-2: 7T vertical magnetCommissioned for Pelican and Quokka. The magnet is currently under commissioning. Please discuss bookings with SE team prior to scheduling.
BT-1Cadex C8000 battery testing
CF-6CF-6: Cryocooler for Reflectometry/SANS, 5K - 300KBottom loader designed to fit into the electromagnet HM-3, can be used with EF-1; it has a manual sample rotation stageTemp Range: 5K - 300K
DSC-1DSC-1: Differential Scanning Calorimeter, -50°C - +350°CDSC for in-situ SANS experimentsTemp Range: -50C - +350C
EC-1EC-1: C shaped Eulerian CradleC shaped eulerian cradle; can accommodate CF-5
EF-1EF-1: Electric Field, 10 kV10kV DC variable power supply system Voltage: up to 10kV
GD-1GD-1: Gas Delivery and Sorption/Desorption System, max. pressure 200 barHiden Isochema IMI-HTP volumetric/manometric system for in-situ sorption/desorption measurements Pressure: max 200 bar
GS-1GS-1: Dynamic Sampling Gas Spectrometer, 1-200 AMUHiden Gas Spectrometer HPR-20 100 mbar - 2 barPressure Range: 100 mbar - 2 bar
HM-1HM-1: 5T horizontal field cryomagnet (dry), B < 5T5 Tesla, 80 mm warm bore, can be used with CF-1/CF-3 cryofurnace
HM-2HM-2: 10T horizontal field magnet (wet), 1.5K – 300K; B <10T10 Tesla horizontal field magnet, can reach 11 T with lambda plate, can use 3he one-shot for 500mK - 80K temps.
HM-3HM-3: 1T Electromagnet, B < 1T1 Tesla Bruker Electromagnet, can be used with cryocooler CF-6. Predominantly used on Platypus as a horizontal magnet. Can be used on Quokka, Bilby and Wombat (for polarisation experiments) as a vertical magnet.
OS-1OS-1: 3He one-shot fridge, 0.5K - 80KHelium 3 one-shot fridge (0.5 K for 8 hours) to be used with the Orange Cryostat OC-1 or 10T Horizontal Magnet HM-2 (Quokka)Temp Range: 0.5K - 80K
RH-1RH-1: Shear cell / rheometer, -40°C - +80°CRheometer for SANS experiments based on Anton_Paar MCR 500 modelTemp Range: -40C - +80C
RQ-1RQ-1: Rapid Heat and Quench Cell, 150K - 700KRapid thermal system for SANS, it allows rapid quenching/heating of samplesTemp Range: 150K - 700K
RV-1RV-1: Rapid Viscosity AnalyserRapid Viscosity Analyser
SC-2SC-2: 20 position SANS sample changer , -40°C - +120°CThermally controlled sample changer for 20 samplesTemp Range: -10C - +80C
SC-7SC-7: SANS 5 Position Rotating Tumbler, RT5 position rotating sample tumbler for QUOKKA and BILBY. Holds round Banjo-style Hellma cells of differing path lengths. Room temperature only.
SC-8SC-8: 12 position SANS sample changerThermally controlled sample changer for 12 samplesTemp Range: -20C - +90C
SF-1SF-1: Stopped Flow mixing cell, 0.01mlAble to rapidly mix fluids as small as 0.01ml
SPC-1SPC-1: SANS 350MPa pressure cell, 0°C - 50°CPressure cell for SANS experimentsTemp Range: 0C - 50C
ST-1ST-1: Sample Tumbler - Rotating / Stirring CellSample Tumbler for SANS experiments
TB-1Temperature bath (TB-1) Julabo LH 45 -50C to 200C-50C - 250C
TB-3Temperature bath (TB-3) Julabo FP40 -20C to 120C-50C-250C
TB-4Temperature Bath (TB-4) Julabo FP50ME 5C-90C
TB-5Temperature Bath (TB-5) Julabo FP50HE 5C-90C
VD-1VD-1: Vapour Delivery System static/dynamic, RT-50 °CHiden Isochema XCS environmental system for in-situ static/dynamic vapour deliveryTemp Range: RT-50 C
Local filling station for polarised 3HeUsed to transfer gas into analyser cell installed in instrument
DEC-1: Vacuum/Gas Chamber Temp range -20C to 150C For gas, vapour and vacuum experiments 100mm quartz windows